S E C T I O N 1

Features and Installation Highlights

This manual applies to the following Honeywell security systems:

ADEMCO VISTA-20P/ADEMCO VISTA-20PSIA/ADEMCO VISTA-20PCN (collectively referred to as VISTA-20P series), ADEMCO VISTA-15P/ADEMCO VISTA-15PSIA/ADEMCO VISTA-15PCN (collectively referred to as VISTA-15P series)

Features and procedures apply to all, except where differences are noted.

SIA Installations: The VISTA-20PSIA and VISTA-15PSIA are certified SIA-compliant controls that meet SIA specifications for False Alarm Reduction. The other controls described in this manual are not certified as SIA compliant, but can be programmed for False Alarm Reduction. To program for False Alarm Reduction, follow the SIA Guidelines noted in the applicable programming fields.

NOTE: Throughout this manual, device model numbers are ADEMCO model numbers unless otherwise noted.

Capabilities and Functions

Feature/Function

ADEMCO VISTA-20P Series

ADEMCO VISTA-15P Series

Partitions

• 2 partitions, can protect two independent

VISTA-15P is not a partitioned system.

 

areas

 

 

• Common zone option allows either

 

 

partition to arm, while leaving a common

 

 

area (ex. lobby or foyer) disarmed for

 

 

access into the other partition.

 

Zones

Up to 48 protection zones plus 16 keyfob

Up to 32 zones plus 8 keyfob zones (zones

 

zones (zones 49-64) for total of 64 zones:

49-56) for total of 40 zones:

 

• 8 basic hardwired zones (zones 1-8) with

• 6 basic hardwired zones (zone 1-6)

 

optional zone-doubling feature

• Up to 16 additional wired zones (zones 9-

 

• Up to 40 additional wired zones (zones 9-

24) using up to 2 4219/4229 modules

 

48) using up to 5 4219/4229 modules

• Up to 26 wireless transmitter zones

 

• Up to 40 wireless transmitter zones (5800

(5800 series; zones 9-34)

 

series; zones 9-48)

• Up to 2 configurable zone types

 

• Up to 4 configurable zone types

 

Security Codes

Up to 48 Security Codes, with separate

Up to 32 Security Codes, with separate

 

authority levels and partition access

authority levels

One-button arming

Dedicated keys can arm the system.

Dedicated keys can arm the system.

Schedules

Up to 32; can control devices and/or auto-

Up to 8; can control devices and/or auto-

 

arm/disarm

arm/disarm

Keypad macros

Up to 4; activated by wired keypads

Up to 2; activated by wired keypads

Paging

Up to 4 pagers; certain system conditions

Up to 2 pagers; certain system conditions

 

can report to pagers; can use a dedicated

can report to pagers; can use a dedicated

 

key on keypads to send a signal to a pager

key on keypads to send a signal to a pager

Event Logging

100 events; log display is done via Ademco

50 events; log display is done via Ademco

 

Compass Downloader software or

Compass Downloader software or

 

installer/master code at Keypad

installer/master code at Keypad

Zone descriptors

Can assign for all zones (for alpha display keypads and/or 4285/4286 Phone Module).

Bell supervision

Optional, detects external sounder wiring short or open; causes a trouble condition,

 

keypad display, and sends a report to the central monitoring station, if enabled.

RF jam detection

Optional, for wireless systems detects a condition that may impede proper RF reception

 

(i.e., jamming or other RF interference); causes keypad display, and sends a report to the

 

central monitoring station (if trouble reporting is enabled).

Telephone Line

Built-in option can monitor the telephone line voltage and can cause a local display, or a

Monitoring

display and trouble/alarm sound

 

Downloading

Via an IBM compatible computer, Compass downloading software, and a compatible

 

HAYES or CIA modem specified by Ademco.

 

1-1