Table 3-2:Card Properties Window Elements (Continued)

Element

Description

Operational State field

Displays the general condition of the interface card. The general

 

condition may appear as any of the following:

 

unknown

 

normal

 

wrong-image

 

bootFailed

 

tooHot

 

booting

 

A condition of unknown indicates an unsupported interface

 

card. To address this condition, replace the card with a

 

supported card.

 

The operational state of a card must appear as normal for the

 

current status of the card to appear as up.

 

A wrong-imagecondition indicates that the active system

 

image on the interface card does not match the active system

 

image on the controller. All cards must run the same active

 

system image as the controller card to function.

 

A bootFailed condition indicates that the active system image

 

on the card was incompletely or incorrectly loaded. If the other

 

interface cards come up successfully, reset the individual card.

 

Otherwise, reboot your entire device.

 

When your card overheats, the tooHot condition appears in the

 

show card command output. Enter the show fan command to

 

check to see if your fans failed.

 

The booting condition indicates that the card has not finished

 

loading necessary image data for internal configuration.

 

 

Boot Stage field

Boot Stage appears as one of the following:

 

recovery

 

ipl

 

ppcboot

 

fpga

 

pic

 

ib

 

rootfs

 

kernel

 

exe

 

done

 

none

 

 

 