HP 377707-002 manual Viewing SRP Hosts Initiators, SRP Initiator ID, Ports Registered With

Models: 377707-002

1 92
Download 92 pages 3.42 Kb
Page 78
Image 78

70

Uncheck the checkbox and grant all new initiators access to ports.

b.(Optional) Click the Restricted checkbox in the LUN Access field to:

Check the checkbox and deny all new initiators access to LUNs.

Uncheck the checkbox and grant all new initiators access to LUNs.

4.Configure random access device attributes:

a.(Optional) Enter an integer value between 1 and 256 in the ITL HI Mark field.

b.(Optional) Enter an integer value between 1 and 100 in the ITL Max Retries field.

c.(Optional) Enter an integer value between 1 and 1800 in the ITL Min I/O Timeout field.

d.(Optional) Click one of the following, in the ITL Dynamic Loading field:

The Path Affinity radio button to enable dynamic path affinity on all new ITLs

The Gateway Port Load Balancing radio button to enable load balancing between Fibre Channel gateway ports on all new ITLs

The Gateway Port Failover radio button to enable FC gateway port failover for all new ITLs

5.Configure sequential access device attributes:

a.(Optional) Enter an integer value between 1 and 256 in the ITL HI Mark field.

b.(Optional) Enter an integer value between 1 and 100 in the ITL Max Retries field.

c.(Optional) Enter an integer value between 1 and 1800 in the ITL Min I/O Timeout field.

d.(Optional) Click one of the following, in the ITL Dynamic Loading field:

The Path Affinity radio button to enable dynamic path affinity on all new ITLs

The Gateway Port Load Balancing radio button to enable load balancing between Fibre Channel gateway ports on all new ITLs

The Gateway Port Failover radio button to enable FC gateway port failover for all new ITLs

6.Click the Apply button.

Viewing SRP Hosts (Initiators)

To view the SRP hosts that connect to your device and, with your Server Switch, behave as FC initiators:

7.Expand the Fibre Channel icon in the Tree frame.

8.Click the SRP Hosts branch. A SRP Hosts table that includes all SRP hosts that connect to the chassis appears in the View frame. Table 7-1lists and describes the fields in this table.

Table 7-1:SRP Hosts Table Fields

Field

Description

Description

User-assigned text description of the SRP host.

 

 

SRP Initiator ID

Host GUID and GUID extension.

 

 

WWNN

Worldwide node name (WWNN) of the SRP host.

 

 

Ports Registered With

Port(s) on your Server Switch that connect to the host.

 

 