HP 377707-002 manual Viewing Node Ports

Models: 377707-002

1 92
Download 92 pages 3.42 Kb
Page 58
Image 58

50

Table 5-7:Switch Properties Window Fields (Continued)

Field

Description

Linear FDB Top

Specifies the top of the linear forwarding table. Packets

 

received with unicast LIDs greater than this value are

 

discarded by the switch. This parameter applies only to

 

switches that implement linear forwarding tables and is

 

ignored by switches that implement random forwarding

 

tables.

 

 

Default Port

Specifies the default port to forward all the unicast packets

 

from other ports whose destination local identifier (DLID)

 

does not exist in the random forwarding table.

 

 

Default Primary MCast Port

Specifies the default port to forward all the multicast packets

 

from other ports whose DLID does not exist in the multicast

 

forwarding table.

 

 

Default Non-Primary MCast

Specifies the port to forward all the multicast packets from

Port

default-pri-mcast-port whose DLID does not exist in the

 

multicast forwarding table.

 

 

Lifetime Value

Specifies the duration a packet can live in the switch. Time

 

units are in milliseconds. Refer to section 18.2.5.4,

 

Transmitter Queueing, “InfiniBand® Architecture, Vol. 1,

 

Release 1.0”, for more information.

 

 

Switch Port State Change

Indicates a change in port state. The value changes from

 

NotInTransition to PortInTransition anytime the State

 

parameter of a port changes from down to initialize, initialize

 

to down, armed to down, or active to down, as a result of

 

link state machine logic.

 

 

LID Per Port

Number of LID/LMC combinations that may be assigned to a

 

given external port for switches that support the random

 

forwarding table. This value is always 0. 0 indicates that there

 

is one LID per port.

 

 

Partition Enforce Cap

Number of entries in this partition enforcement table per

 

physical port. Zero (0) indicates that partition enforcement is

 

not supported by the switch.

 

 

In Enforce Cap

Indicates if the switch is capable of partition enforcement on

 

received packets. The value is true or false.

 

 

Out Enforce Cap

Indicates if the switch is capable of partition enforcement on

 

transmitted packets. The value is true or false.

 

 

In Filter Raw Packet Cap

Indicates if the switch is capable of raw packet enforcement

 

on received packets. The value is true or false.

 

 

Out Filter Raw Packet Cap

Indicates if the switch is capable of raw packet enforcement

 

on transmitted packets. The value is true or false.

Viewing Node Ports

To view the IB ports on a node in your IB fabric:

1.Expand the InfiniBand icon in the Tree frame.

2.Expand the Topology icon in the IB frame.

3.Click the Nodes branch. The Nodes table appears in the View frame.

Page 58
Image 58
HP 377707-002 manual Viewing Node Ports