kug-appc Page 5 Thursday, March 6, 1997 4:51 PM

M e m o r y S I M M s

Installing aMemory SIMM

SIMMs and controller boards are sensitive to static electricity. Before installing a SIMM, discharge static electricity from

your body by touching something metal, such as the metal

Caution back plate on any device plugged into a grounded power source. If you walk around before finishing the installation,

again discharge any static electricity.

Never remove the printer controller board while the printer is plugged in.

 

1 MB of the printer’s resident memory is unusable for each

 

32

MB SIMM that is installed. Therefore, when you install

 

one 32 MB SIMM the total system memory is 33MB, not

Note

34

MB. When two 32 MB SIMMs are installed, the total

 

system memory is 64 MB, not 66 MB.

 

 

 

1 Power OFF the printer and disconnect the power cord and any interface cables.

2 Loosen the thumb screws and pull out the

3 Place the controller board on a ream of

controller board.

paper.

A p p e n d i x C : I n s t a l l i n g a n d R e m o v i n g P r i n t e r O p t i o n s C-5