ZCOM Tables and Data Structures
Interface Table
ISTIME - Time of last ZMON restart/shutdown this card.
This field contains the time (seconds since the Epoch) when ZMON last processed a restart or shutdown request for this card. It is used internally by ZMON to detect and ignore multiple restart/shutdown requests.
BC1_ADDR - First level bus converter address for this MUX interface card
For HP9000 Series K systems the address is of the form bc1/bc/s. This field refers to the first level bus converter address indicated as bc1. For other systems this field is initialized to zero.
BC_ADDR - Bus converter address for this MUX interface card
This field contains the I/O bus converter address representing the I/O bus that the MUX interface card is installed in. On systems that contain only one I/O bus (S8x7, I30, H50, etc), this field is initialized to zero.
CARD_ADDR - Card address for this MUX interface card
This field contains the I/O card address representing the I/O slot number that the MUX interface card is installed in. It is initialized by TTGEN from the slot value specified in the MUX statement of the TTGEN configuration file.
INHPA - Interface HPA value (from TTGEN)
The HPA value is built as follows:
Table | Interface HPA Value INHPA |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 11 |
| ||
|
|
|
|
|
|
|
|
|
All 1’s (111...) | 1111 | Bus | Slot | Module | Page | Register | Reg No. | 00 |
|
| Address |
|
|
| Set |
|
|
|
|
|
|
|
|
|
|
|
For the Mux interface in an
Chapter 3 | 77 |