e.Pull out the microprocessor tray until it stops; then, push in on the microprocessor tray retention latches on each side of the tray and pull the tray out of the server.

Attention: The microprocessor tray is heavy. Pull the tray partially out of the server, reposition your hands to grasp the body of the tray, and press in on the release latches on each side of the tray; then, pull the tray out the rest of the way.

Air baffle

Heat sink

FRONT

 

Microprocessor

FRONT

FRONT

FRONT

Microprocessor baffle

VRM 4

Note: The new microprocessor comes in a kit with a VRM and a heat sink. The VRM is used only with a microprocessor that is installed in socket 3 or 4.

4.Lift the air baffle out of the microprocessor tray.

5.Remove the microprocessor baffle from a microprocessor socket and store it for future use.

6.Remove the protective cover, tape, or label from the surface of the microprocessor socket, if any is present.

7.Lift the microprocessor-release lever to the fully open position (approximately 135° angle).

Chapter 2. Installing options 45

Page 57
Image 57
IBM 71455DU manual Air baffle Heat sink