IBM 71455DU Baseboard management controller BMC settings, BMC firmware Ver, BMC Post Watchdog

Models: 71455DU

1 110
Download 110 pages 11.7 Kb
Page 73
Image 73

Baseboard management controller (BMC) settings

Select this choice to view information and to change baseboard management controller (BMC) settings.

-BMC firmware Ver

This is a nonselectable menu item that displays the BMC firmware version.

-BMC POST Watchdog

Enable or disable the BMC POST watchdog. Disable is the default setting.

-BMC POST Watchdog Timeout

Set the BMC POST watchdog timeout value. 5 minutes is the default setting.

-System BMC Serial Port Sharing

Enable or disable the system BMC serial port sharing. Enable is the default setting.

-BMC Serial Port Access Mode

Share or disable the BMC serial port access mode. Shared is the default setting.

-Reboot system on NMI

If you enable this option, the server automatically restarts 60 seconds after the service processor issues a nonmaskable interrupt (NMI) to the server. If you disable this option, the server does not restart. Enable is the default setting.

-BMC Network Configuration

Select this choice to view the BMC Network Configuration information.

-BMC System Event Log

Select this choice to view the BMC system event log, which contains all system error and warning messages that have been generated. Use the arrow keys to move between pages in the log. If an optional IBM Remote Supervisor Adapter II SlimLine is installed, the full text of the error messages is displayed; otherwise, the log contains only numeric error codes. Run the diagnostic program to get more information about error codes that occur. See the Problem Determination and Service Guide on the IBM System x Documentation CD for instructions. Select Clear error logs to clear the BMC system event log.

v Error Logs

Select this choice to view or clear error logs.

This choice is available on the full Configuration/Setup Utility menu only.

POST Error Log

Select this choice to view the three most recent error codes and messages that were generated during POST. Select Clear error logs to clear the POST error log.

vSave Settings

Select this choice to save the changes that you have made in the settings.

vRestore Settings

Select this choice to cancel the changes that you have made in the settings and restore the previous settings.

vLoad Default Settings

Select this choice to cancel the changes you have made in the settings and restore the factory settings.

vExit Setup

Chapter 3. Configuring the server 61

Page 73
Image 73
IBM 71455DU Baseboard management controller BMC settings, BMC firmware Ver, BMC Post Watchdog Timeout, Error Logs