Table 8. NSBxxxx error codes and text messages (continued)

Error code

Error message

What you should do

 

 

 

NSB21500

Audio failure.

Replace the thin client logic unit (see

 

 

“Appendix A. Replacing hardware parts”

 

 

on page 41).

 

 

 

Input, keyboard and mouse messages (NSB3xxxx, NSB31xxx, and NSB32xxx)

 

 

 

NSB30500

No input device detected.

Check the keyboard and mouse cable

 

NS Boot will continue in

connections.

 

10 seconds.

 

 

 

 

NSB31500

Keyboard did not

Check the keyboard cable connection.

 

respond.

 

 

 

 

NSB31510

Keyboard controller did

Check the keyboard and mouse cable

 

not respond.

connections. If the symptom remains,

 

 

replace the thin client logic unit (see

 

 

“Appendix A. Replacing hardware parts”

 

 

on page 41).

 

 

 

NSB31520

Keyboard was not

Check the keyboard cable connection.

 

recognized.

 

 

 

 

NSB32500

Mouse did not respond.

Check the mouse cable connection.

 

 

 

 

USB messages (NSB4xxxx)

 

 

 

NSB40500

USB failure.

Disconnect any USB devices from the thin

 

 

client and restart the system. If the

 

 

symptom remains, replace the thin client

 

 

logic unit (see “Appendix A. Replacing

 

 

hardware parts” on page 41).

 

 

 

NSB40510

USB initialization failure.

Disconnect any USB devices from the thin

 

 

client and restart the system. If the

 

 

symptom remains, replace the thin client

 

 

logic unit (see “Appendix A. Replacing

 

 

hardware parts” on page 41).

 

 

 

 

CompactFlash card messages (NSB51xxx)

 

 

 

NSB51500

File not found on flash

Check the contents of the CompactFlash

 

card.

card.

 

 

 

NSB51510

Cannot close file on flash

Check the contents of the CompactFlash

 

card.

card.

 

 

 

 

Ethernet messages (NSB62xxx)

 

 

 

NSB62500

Line speed automatic

Verify that you connected the network

 

negotiation failed.

cable to the thin client correctly.

 

 

 

NSB62510

No network device

Replace the thin client logic unit (see

 

found.

“Appendix A. Replacing hardware parts”

 

 

on page 41).

 

 

 

 

Network priority messages (NSB7xxxx)

 

 

 

NSB70500

DHCP, BOOTP, and Local

Verify that at least one network priority is

 

(NVRAM) network

enabled in the NS Boot utility.

 

priority not set.

 

 

 

 

 

DHCP messages (NSB71xxx)

Most errors associated with DHCP are server configuration errors, contact the system

administrator and report your error.

38

Page 48
Image 48
IBM N2800e manual Error code Error message What you should do, USB messages NSB4xxxx, CompactFlash card messages NSB51xxx