0.3 DECALS (continued)

Compressor Package Data

COMPRESSOR MODEL

m3/MIN

CAPACITY

RATED OPERATING PRESSURE

BARG

MAX. DISCHARGE PRESSURE

BARG

MAX. MODULATE PRESSURE

BARG

NOMINAL DRIVE MOTOR

KW

NOMINAL FAN MOTOR

KW

TOTAL PACKAGE AMPS...............................

VOLTS............................................................

PHASE / HERTZ............................................

CONTROL VOLTAGE.....................................

SERIAL NUMBER..........................................

CONTACTOR AMP. RATING.....................................

ASSEMBLY AMP. RATING........................................

LOCKED ROTOR AMP. RATING OF ASSY. ............

AIR SOLUTIONS GROUP

DAVIDSON, NORTH CAROLINA 28036 54425996 Rev.C

WWW.AIR.INGERSOLL-RAND.COM

54425996 Rev. C (75-160 KW) - 2 REQUIRED

Electrical

power inlet.

39541354 Rev 03

!WARNING

Hazardous voltage. Can cause severe injury or death.

Only use factory supplied inlet for incoming power. See Operators/

Instruction Manual.

39543764 Rev. 03

NOTICE

IEC Starter Overload Setting

Compressor Package Data

COMPRESSOR MODEL

CFM

CAPACITY

PSIG

RATED OPERATING PRESSURE

PSIG

MAX. DISCHARGE PRESSURE

PSIG

MAX. MODULATE PRESSURE

H.P.

NOMINAL DRIVE MOTOR

H.P.

NOMINAL FAN MOTOR

TOTAL PACKAGE AMPS...............................

VOLTS............................................................

PHASE / HERTZ............................................

CONTROL VOLTAGE.....................................

SERIAL NUMBER..........................................

CONTACTOR AMP. RATING.....................................

ASSEMBLY AMP. RATING........................................

LOCKED ROTOR AMP. RATING OF ASSY. ............

AIR SOLUTIONS GROUP

DAVIDSON, NORTH CAROLINA 28036 39557095 Rev.05

WWW.AIR.INGERSOLL-RAND.COM

39557095 Rev.05 (100-200 HP) - 2 REQUIRED

!WARNING

Hazardous voltage. Can cause severe injury or death.

Only use factory supplied inlet for incoming power. See Operators/

Instruction Manual.

39543764 Rev. 04

!WARNING

Hazardous voltage. Can cause severe injury or death.

Disconnect power before servicing. Lockout/Tagout machine.

39540174 Rev. 05

1.Full-Voltage Starter (Main or Fan Motor): Multiply MOTOR nameplate amps by 1.11.

Star-Delta Starter (Main motors only): Multiply MOTOR nameplate amps by 0.64.

2.Set corresponding overload relay at this value.

3.Never exceed the following limits:

Full-Voltage Starter: 125% of MOTOR nameplate amps.

Star-Delta Starter: 72% of MOTOR nameplate amps.

39921804 Rev. B

SCHEMATIC DECAL

VOLTAGE DECAL OPTION INSIDE STARTER BOX ON RIGHT SIDE

7