Chapter 12: Installing the SRX210 Services Gateway

Chapter 12: Installing the SRX210 Services Gateway

To accommodate the 150-watt power supply, use the 420–028535 screw to attach the adapter stopper bracket at the point on the chassis marked A.

Figure 16 on page 71 shows the adjustments to the power supply adapter tray required for the 150-watt power supply.

Figure 16: Adjusting the Power Supply Adapter Tray to Accommodate the 150-Watt Power Supply

1.Locations for the adapter stopper brackets in the power supply adapter tray

2.Fully configured power supply adapter tray

Related Topics Preparing the SRX210 Services Gateway for Rack-Mount,Desk-Mount, and Wall-Mount Installation on page 65

Preparing the SRX210 Services Gateway for Rack-Mount Installation on page 66

Installing the SRX210 Services Gateway in a Rack

You can front-mount the SRX210 Services Gateway in a rack. Many types of racks are acceptable, including four-post (telco) racks, enclosed cabinets, and open-frame racks. For more information about the type of rack or cabinet the SRX210 Services Gateway can be installed into, see “SRX210 Services Gateway Rack Requirements” on page 52.

NOTE: The rack-mounting kit is not shipped with the device and must be ordered separately.

Installing the SRX210 Services Gateway in a Rack 71