Preparing the SRX210 Services Gateway for Rack-Mount Installation

SRX210 Services Gateway Hardware Guide

Preparing the SRX210 Services Gateway for Rack-Mount Installation

You can mount an SRX210 Services Gateway on four-post (telco) racks, enclosed cabinets, and open-frame racks.

NOTE: The SRX210 Services Gateway cannot be center-mounted in racks.

Table 28 on page 66 provides the list of tasks you need to perform before installing the device.

Table 28: SRX210 Services Gateway Preinstallation Checklist for Rack-Mount

Installation

Task

Verify that the site meets the requirements.

Verify that the racks or cabinets meet the specific requirements.

Place the rack or cabinet in its permanent location, allowing adequate clearance for airflow and maintenance, and secure it to the building structure.

Remove the services gateway chassis from the shipping carton.

Verify that you have the following parts available in your rack-mounting kit for the SRX210 Services Gateway:

Rack-mounting brackets

Mounting screws

Power supply adapter tray with screws

Adapter stopper bracket

Adjust the power supply adapter tray.

Additional Information

“Site Preparation Checklist for the SRX210 Services Gateway” on page 49

“SRX210 Services Gateway Rack Requirements” on page 52

“Clearance Requirements for Airflow and Hardware Maintenance of the SRX210 Services Gateway” on page 54

“Unpacking the SRX210 Services Gateway” on page 61

“Adjusting the Power Supply Adapter Tray for the SRX210 Services Gateway for Rack-Mount Installation” on page 70

NOTE: The rack-mounting kit is not shipped with the device and must be ordered separately.

66Preparing the SRX210 Services Gateway for Rack-Mount Installation