Juniper Networks SRX 210 manual Component LEDs on the Services Gateway continued

Models: SRX 210

1 200
Download 200 pages 27.83 Kb
Page 141
Image 141
Table 43: Component LEDs on the Services Gateway (continued)

Chapter 18: Monitoring the SRX210 Services Gateway

Table 43: Component LEDs on the Services Gateway (continued)

LED

State

Meaning

Power LED

Green

The device is receiving

 

 

power and is functioning

 

 

normally.

 

Amber

The Power button has been

 

 

pressed and quickly

 

 

released.

 

Off

The device is not receiving

 

 

power.

HA LED

Off

 

Mini-PIM LED

Green

The Mini-PIM is present and

 

 

detected by the device.

 

Off

The Mini-PIM is not present

 

 

or is not detected by the

 

 

device.

Possible Causes and Corrective Actions

Normal condition. No action is required.

Normal condition. No action is required.

Normal condition if the services gateway is switched off. No action is required.

If you have not powered off the services gateway, verify that the AC power cord from the power source to the device is not damaged, the socket is in working condition, and the device has an AC input voltage between 110 and 240 VAC.

See “Monitoring the SRX210 Services Gateway Power System” on page 125.

The device is not part of the chassis cluster setup.

Normal condition. No action is required.

See “Monitoring the SRX210 Services Gateway Using Chassis Alarm Conditions” on page 122.

Monitoring the SRX210 Services Gateway Components Using LEDs 121

Page 141
Image 141
Juniper Networks SRX 210 manual Component LEDs on the Services Gateway continued