Table 46: Site Electrical Wiring Guidelines for the Services Gateway (continued)

Site Wiring Factor

Guideline

Radio Frequency

To reduce or eliminate the emission of RFI from your site wiring:

Interference (RFI)

Use twisted-pair cable with a good distribution of grounding

 

 

conductors.

 

Use a high-quality twisted-pair cable with one ground conductor for

 

each data signal when applicable, if you must exceed the

 

recommended distances.

Electromagnetic

Provide a properly grounded and shielded environment and use electrical

Compatibility (EMC)

surge-suppression devices.

Strong sources of electromagnetic interference (EMI) can cause the following damage:

Destroy the signal drivers and receivers in the device

Conduct power surges over the lines into the equipment, resulting in an electrical hazard

NOTE: If your site is susceptible to problems with EMC, particularly from lightning or radio transmitters, you may want to seek expert advice.

CAUTION: To comply with intrabuilding lightning/surge requirements, the intrabuilding wiring must be shielded. The shielding for the wiring must be grounded at both ends.

Related Topics General Site Guidelines for Installing the SRX210 Services Gateway on page 51

SRX210 Services Gateway Electrical and Power Requirements on page 55

SRX210 Services Gateway Power Specifications and Requirements on page 158

SRX210 Services Gateway Power Specifications and Requirements

The AC power system electrical specifications for the SRX210 Services Gateway are listed in Table 47 on page 158.

Table 47: Power Supply Electrical Specifications for the SRX210 Services Gateway

Power Requirement

Specification

AC input voltage

100 to 240 VAC

AC input line frequency

50 to 60 Hz