Function Mode and Adjustment

6

6.Referring to the setting procedure for Function mode, set "F7".

7.To perform the adjustment, press the Start key.

8.Rotate VR61 on PU2 so that the reading voltage on the multi- meter becomes DC21.5±0.2V.

9.Cancel the Function Mode.

10.Check the Projection Lamp voltage in reader mode is DC17.0±0.3V.

VR61

PU2

NOTE

In order to prevent damage of the Projection Lamp be careful of the following items in adjustment.

Do not exceed the DC21.7V during Projection Lamp voltage adjustment.

Makes full lighting time in F7 mode of the Projection Lamp into less than 30 seconds.

6.8.8 F8: Reset the Setting Data

Function mode setting value and job program are reset to the default value.

1.Sets the function mode “F8”.

2.Press the Mode Memory Key.

3.A display window blinks and setting data is cleared.

101

Page 108
Image 108
Kodak 2400DSV service manual PU2, 8 F8 Reset the Setting Data