Disassembly and Cleaning

5

5.4.10 Replacing Scan Motor bushing and friction plate

1 Remove the Optical Cover. (2 screws)

2 Tilt the Scan Motor Assy in the direction of the arrow and, pressing the shaft in the direction of the arrow, re-move the bushing and then peel the friction plate off the Scan Motor Assy.

NOTE:

Do not lose the pin.

Scan Motor

spring

friction plate Pin bushing

5.4.11 Replacing the Fuse of the Power Unit

1 Remove the Optical Cover. (2 screws)

73

Page 80
Image 80
Kodak 2400DSV service manual Replacing Scan Motor bushing and friction plate, Replacing the Fuse of the Power Unit