7
Troubleshooting
7.6Electrical Components Check
7.6.1 LA1: Projection Lamp
1
Is the circuit across both terminals of the Lamp conducting when the Lamp is removed from the machine?
→No | Replace LA1. |
|
|
→Yes | OK |
|
|
7.6.2M3: Power Unit Cooling Fan Motor
1 | Does the Motor start rotating when the Power | →Yes | OK |
| ON/OFF Switch is turned ON? |
|
|
|
|
|
|
| ↓ No |
|
|
|
|
|
|
2 | Is the voltage across | →No | Check wiring. |
| DC24V with the Power Switch in the ON |
|
|
| →Yes | Replace M3. | |
| position? | ||
|
|
|
|
7.6.3M4: Projection Lamp Cooling Fan Motor
1 | Does the Motor start rotating when the Power | →Yes | OK |
| ON/OFF Switch is turned ON? |
|
|
|
|
|
|
| ↓ No |
|
|
|
|
|
|
2 | Is the voltage across | →No | Check wiring. |
| DC24V with the Power ON/OFF Switch in the |
|
|
| →Yes | Replace M4. | |
| ON position? | ||
|
|
|
|
7.6.4PC1: Image Leading Edge Sensor
1 | Is the voltage across | →No | Replace PC1. |
| and GND 0V when the Power Switch is in the |
|
|
| ON position and the light emitted by the |
|
|
| Sensor LED is blocked? |
|
|
|
|
|
|
| ↓ Yes |
|
|
|
|
|
|
2 | Is the voltage across | →No | Replace PC1. |
| and GND DC5V when the light emitted by the |
|
|
| →Yes | OK | |
| Sensor LED strikes the Sensor | ||
| photosensitive element? |
|
|
|
|
|
|
7.6.5PC2: Scan Mirror Position Sensor
1 | Is the voltage across | →No | Replace PC2. |
| and GND 0V when the Power Switch is in the |
|
|
| ON position and the light emitted by the |
|
|
| Sensor LED is blocked? |
|
|
|
|
|
|
| ↓ Yes |
|
|
|
|
|
|
2 | Is the voltage across | →No | Replace PC2. |
| and GND DC5V when the light emitted by the |
|
|
| →Yes | OK | |
| Sensor LED strikes the Sensor | ||
| photosensitive element? |
|
|
|
|
|
|
114