7

Troubleshooting

7.6Electrical Components Check

7.6.1 LA1: Projection Lamp

1

Is the circuit across both terminals of the Lamp conducting when the Lamp is removed from the machine?

→No

Replace LA1.

 

 

→Yes

OK

 

 

7.6.2M3: Power Unit Cooling Fan Motor

1

Does the Motor start rotating when the Power

→Yes

OK

 

ON/OFF Switch is turned ON?

 

 

 

 

 

 

 

↓ No

 

 

 

 

 

 

2

Is the voltage across CN10-1 and GND

→No

Check wiring.

 

DC24V with the Power Switch in the ON

 

 

 

→Yes

Replace M3.

 

position?

 

 

 

 

7.6.3M4: Projection Lamp Cooling Fan Motor

1

Does the Motor start rotating when the Power

→Yes

OK

 

ON/OFF Switch is turned ON?

 

 

 

 

 

 

 

↓ No

 

 

 

 

 

 

2

Is the voltage across CN18-1 and GND

→No

Check wiring.

 

DC24V with the Power ON/OFF Switch in the

 

 

 

→Yes

Replace M4.

 

ON position?

 

 

 

 

7.6.4PC1: Image Leading Edge Sensor

1

Is the voltage across PJ8-A3 on PWB-BB

→No

Replace PC1.

 

and GND 0V when the Power Switch is in the

 

 

 

ON position and the light emitted by the

 

 

 

Sensor LED is blocked?

 

 

 

 

 

 

 

↓ Yes

 

 

 

 

 

 

2

Is the voltage across PJ8-A3 on PWB-BB

→No

Replace PC1.

 

and GND DC5V when the light emitted by the

 

 

 

→Yes

OK

 

Sensor LED strikes the Sensor

 

photosensitive element?

 

 

 

 

 

 

7.6.5PC2: Scan Mirror Position Sensor

1

Is the voltage across PJ8-B15 on PWB-BB

→No

Replace PC2.

 

and GND 0V when the Power Switch is in the

 

 

 

ON position and the light emitted by the

 

 

 

Sensor LED is blocked?

 

 

 

 

 

 

 

↓ Yes

 

 

 

 

 

 

2

Is the voltage across PJ8-B15 on PWB-BB

→No

Replace PC2.

 

and GND DC5V when the light emitted by the

 

 

 

→Yes

OK

 

Sensor LED strikes the Sensor

 

photosensitive element?

 

 

 

 

 

 

114

Page 121
Image 121