6
Function Mode and Adjustment
6.5.11 Sb: Scan Table Stop Position Adjustment (Scan Position)
This adjustment is necessary when any of the following symptoms occurs.
Symptom 1. | Each time a print is made, the image on the Screen shifts vertically. | |||
|
|
|
|
|
Symptom 2. | The noise becomes big that is heard when the Scan Table hits against | |||
|
|
| the Scan Table Stopper during its motion from the reader position to | |
|
|
| printer position. | |
|
|
|
|
|
|
|
|
| Rear |
|
|
|
|
|
Display | setting |
| Scan Table Stop Position |
|
Sb | d0 |
| toward the rear |
|
|
|
| ||
| d8 |
| center |
|
|
|
| ||
| dF |
| toward the screen |
|
|
|
|
|
|
Screen
*The stop position of the Scan Table should be set toward the rear for symptom 1 explained above and toward the screen for symptom 2.
6.5.12 SC: Scan Table Stop Position Adjustment (Reader Position)
This adjustment is necessary when any of the following symptoms occurs.
Symptom 1. | Each time a print is made, the image on the Screen shifts vertically. | ||
|
|
|
|
Symptom 2. | The noise becomes big that is heard when the Scan Table hits against | ||
|
| the Scan Table Stopper during its motion from the reader position to | |
|
| printer position. | |
|
|
|
|
|
|
| Rear |
|
|
|
|
Display | setting | Scan Table Stop Position |
|
SC | d0 | toward the screen |
|
|
| ||
| d8 | center |
|
|
| ||
| dF | toward the rear |
|
|
|
|
|
Screen
*The stop position of the Scan Table should be set toward the screen for symptom 1 explained above and toward the rear for symptom 2.
88