7.4.7CL: Printer Clock malfunction
Check Item |
| Remedy |
Is CL shown even when power is | →No | OK |
turned OFF, then turned ON again? |
|
|
|
|
|
↓Yes |
|
|
|
|
|
Is the dedicated interface cable used? | →No | Replace the Interface Cable. |
|
|
|
↓Yes |
|
|
|
|
|
Checks the connection of an interface | →No | Reconnect the Interface Cable. |
cable. |
|
|
|
|
|
↓Yes |
|
|
|
|
|
Confirm the frequency of the Oscillator | →NG | Reinstall the Oscillator. |
on |
| or |
|
| Replace the Oscillator. |
When using the MSP3000 Printer |
|
|
OSC1: 42.3158MHz |
|
|
OSC2: 95.2106MHz |
|
|
When using the MSP2000 Printer. |
|
|
OSC1: 19.5332MHz |
|
|
OSC2: None |
|
|
|
|
|
↓OK |
|
|
|
|
|
Replace |
|
|
|
|
|
112