Computer Interface
H4: Parity
Parameter value | Meaning |
|
|
0 | None |
|
|
1 | Odd |
|
|
2 | Even |
|
|
3 | Ignore |
|
|
The factory default setting is None (0 on the status printout).
H5: Protocol logic
Parameter value | Meaning |
|
|
0 | Combination of 1 and 3 below |
|
|
1 | DTR/DSR, positive logic |
|
|
2 | DTR, negative logic |
|
|
3 | XON/XOFF |
|
|
4 | ETX/ACK |
|
|
5 | XON/XOFF recognized only as protocol |
|
|
The factory default setting is 0.
H6: Buffer nearly-full threshold
This is a percentage from 0 to 99. The factory default setting is 90.
H7: Buffer nearly-empty threshold
This is a percentage from 0 to 99. The factory setting is 70.
The factory default settings of the buffer
The gap between the
H8: Received-data buffer size
This is the size of the input buffer, specified in units of 10 Kbytes. The
ADVANCED OPERATION GUIDE |