Computer Interface
PRESCRIBE FRPO D0 command
The PRESCRIBE FRPO D0 command provides control over XON/XOFF operation when an error occurs on the serial interface. The following table summarizes the error status corresponding to different D0 values.
Timing of XON transfer to host | Serial interface error | |
|
| |
|
| |
while Ready or Waiting | Error | Error |
| not resolved | resolved |
|
|
|
XON sent every 3 to 5 seconds | D0=0 | D0=1 |
| (default) |
|
|
|
|
XON not sent | D0=10 | D0=11 |
|
|
|
ADVANCED OPERATION GUIDE |