8: Setup Mode: Advanced Settings

TCP Keepalive time in seconds

This option allows you to change how many seconds the unit waits during a silent connection before attempting to see if the currently connected network device is still on the network. If the unit gets no response, it drops that connection. The default setting is 45.

TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ?

ARP Cache timeout in seconds

Whenever the unit communicates with another device on the network, it adds an entry into its ARP table. The ARP Cache timeout option allows you to define how many seconds (1-600) the unit will wait before timing out this table. The default setting is 600.

ARP Cache timeout in s (1s - 600s) : (600) ?

CPU Performance

Select the WiBox 2100E device server’s performance mode. Higher performance settings require more energy. Low is 26 Mhz, Regular is 48 Mhz, High is 88 Mhz. The default setting is Regular.

CPU performance (0=Regular, 1=Low, 2=High): (0) ?

Notes:

If a baud rate of 460 Kbps or 920 Kbps is set, and the high performance mode is disabled, the operation of the serial channel would be out of the specified error tolerance, thereby leading to inconsistent speed settings on the two ends of the serial channel.

Increasing CPU clock speed consumes more power and generates more heat. This reduces the maximum operating temperature specification. See the appropriate product brief for details.

Disable Monitor Mode at bootup

This option allows you to disable all entries into Monitor Mode during startup, except for the ‘xxx’ sequence. This prevents entry using yyy, zzz, xx1, and yy1 key sequences (only during the bootup sequence). The default setting for Monitor Mode at bootup is N (No). (See 9: Monitor Mode.)

Disable Monitor Mode @ bootup (N) ? _

HTTP Port Number

This option allows the configuration of the web server port number. The valid range is 1-65535. The default setting HTTP port number is 80.

HTTP Port Number : (80) ? _

MTU Size

The Maximum Transmission Unit (MTU) is the largest physical packet size a network can transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default setting is 1400 bytes.

MTU Size: (1400) ? _

WiBox® 2100E Device Server User Guide

68

Page 68
Image 68
Lantronix 2100E TCP Keepalive time in seconds, ARP Cache timeout in seconds, CPU Performance, Http Port Number, MTU Size