9: Monitor Mode

Monitor Mode is a command-line interface used for diagnostic purposes. There are two ways to enter Monitor Mode: locally via the serial port or remotely via the network.

Entering Monitor Mode via the Serial Port

To enter Monitor Mode locally:

1.Follow the same steps used for setting the serial configuration parameters (see 5:Telnet or Serial Port (Setup Mode) Configuration).

2.Instead of typing three x keys, however:

3.Type zzz to enter Monitor Mode with network connections.

4.Type yyy to enter Monitor Mode without network connections.

A 0> prompt indicates that you have successfully entered Monitor Mode.

Entering Monitor Mode via the Network Port

To enter Monitor Mode using a Telnet connection:

1.Establish a Telnet session to the configuration port (9999). The following message displays:

2.MAC address 00204A96559B

3.Software version V6.7.0RC6 (100118)

4.AES Library version 1.8.2.1

5.Press Enter for Setup ModeType M (upper case).

A 0> prompt indicates that you have successfully entered Monitor Mode.

Monitor Mode Commands

The following commands are available in Monitor Mode.

Note: All commands must be in capital letters.

Table 9-1. Monitor Mode Commands

Command

Command Name

Function

 

 

 

VS

Version

Queries software header record (16 bytes) of unit.

 

 

 

GC

Get Configuration

Gets configuration of unit as hex records (120

 

 

bytes).

 

 

 

SC

Send Configuration

Sets configuration of unit from hex records.

 

 

 

WiBox® 2100E Device Server User Guide

75

Page 75
Image 75
Lantronix 2100E manual Entering Monitor Mode via the Serial Port, Entering Monitor Mode via the Network Port