7: Setup Mode: Channel Configuration

Flow

Flow control sets the local handshaking method for stopping serial input/output. The default setting is 00.

Flow (00) ? _

Use the following table to select flow control options:

Table 7-3. Flow Control Options

Flow Control Option

Hex

 

 

No flow control

00

 

 

XON/XOFF flow control

01

 

 

Hardware handshake with RTS/CTS lines

02

 

 

XON/XOFF pass characters to host

05

 

 

Port Number

The setting represents the source port number in TCP connections. It is the number that identifies the channel for remote initiating connections.

Port No (10001) ? _

The default setting for Port 1 is 10001. The range is 1-65535, except for the following reserved port numbers:

 

Table 7-4. Reserved Port Numbers

 

 

 

Port Numbers

 

Reserved for

 

 

 

1 – 1024

 

Reserved (well known ports)

 

 

 

9999

 

Telnet setup

 

 

 

14000-14009

 

Reserved for Redirector

 

 

 

30704

 

Reserved (77F0h)

 

 

 

30718

 

Reserved (77FEh)

 

 

 

Warning: We recommend that you not use the reserved port numbers for this setting as incorrect operation may result.

Use Port 0 for the outgoing local port to change with each connection. The port range is 50,000 to 59,999. Each subsequent connection increments the number by 1 (it wraps back around to 50,000).

Only use this automatic port increment feature to initiate a connection using TCP. Set the port to a non-zero value when the unit is in a passive mode or when using UDP instead of TCP.

WiBox® 2100E Device Server User Guide

51

Page 51
Image 51
Lantronix 2100E manual Flow Control Option Hex, Port Numbers Reserved for