7: Setup Mode: Channel Configuration

 

 

 

 

a) Incoming Connection

 

 

 

Never Accept Incoming

Rejects all external connection attempts.

 

 

 

 

 

 

Accept with active Modem

Accepts external connection requests only when Modem

 

 

Control In

Control In input is asserted. Cannot be used with Modem Mode.

 

 

 

 

 

 

Always Accept

Accepts any incoming connection when a connection is not

 

 

 

already established. Default setting.

 

 

 

 

 

b) Response

 

 

 

Character Response

 

 

 

A single character is transmitted to the serial port when there is a

 

 

 

change in connection state:

 

 

 

C = connected, D = disconnected, N = host unreachable.

 

 

 

Single character mode specifies the character response. The IP

 

 

 

address of the host connecting to the unit displays when the unit

 

 

 

is in verbose mode. This option is overridden when the Active

 

 

 

Start Modem Mode or Active Start Host List is in effect.

 

 

 

Default setting is Nothing (quiet).

 

 

 

 

 

c) Active Startup

 

 

 

No Active Startup

Does not attempt to initiate a connection under any

 

 

 

circumstance. Default setting.

 

 

 

 

 

 

With Any Character

Attempts to connect when any character is received from the

 

 

 

serial port.

 

 

 

 

 

 

With active Modem Control

Attempts to connect when the Modem Control In input changes

 

 

In

from not asserted to asserted.

 

 

 

 

 

 

With a Specific Start

Attempts to connect when it receives a specific start character

 

 

Character

from the serial port. The default start character is carriage return.

 

 

 

 

 

 

Manual Connection

Attempts to connect when directed by a command string

 

 

 

received from the serial port. The first character of the command

 

 

 

string must be a C (ASCII 0x43), and the last character must be

 

 

 

either a carriage return (ASCII 0x0D) or a line feed (0x0A). No

 

 

 

blanks or space characters may be in the command string.

 

 

 

Between the first and last command string characters must be a

 

 

 

full or partial destination IP address and may be a destination

 

 

 

port number.

 

 

 

The IP address must be in standard decimal-dot notation and

 

 

 

may be a partial address, representing the least significant 1, 2,

 

 

 

or 3 bytes of the remote IP address. The period is required

 

 

 

between each pair of IP address numbers.

 

 

 

If present, the port number must follow the IP address, must be

 

 

 

presented as a decimal number in the range 1-65535, and must

 

 

 

be preceded by a forward slash (ASCII 0x2F). The slash

 

 

 

separates the IP address and the port number. If you omit the

 

 

 

port number from a command string, the internally stored remote

 

 

 

port number starts a connection.

 

 

 

If a partial IP address is presented in a command string, it is

 

 

 

interpreted to be the least significant bytes of the IP address and

 

 

 

 

 