8: Setup Mode: Advanced Settings

Expert Settings (Option 5)

Note: You can change these settings using Telnet or serial connections only, not Web Manager.

Caution: Only an expert should change these parameters. You must definitely know the consequences the changes may have.

Figure 8-1. Expert Settings

TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ?

ARP Cache timeout in s (1s - 600s) : (600) ?

CPU performance (0=Regular, 1=Low, 2=High): (0) ?

Disable Monitor Mode @ bootup (N) ?

HTTP Port Number : (80) ?

MTU Size (512 - 1400): (1400) ?

TCP Re-transmission Timeout (500 - 4000) (ms): (500) ?

Enable alternate MAC (N) ?

Ethernet connection type: (0) ?

Note: The Config Server Port Number option and Automatic Host MAC Detection option display only in Bridging mode as shown in the next window. For more information, see Configurable Server Port Number and Automatic Host MAC Detection on page 69.

The default settings are listed below:

TCP Keepalive time in s

45

(1s – 65s; 0s=disable)

 

ARP Cache timeout in s

600

(1s – 600s)

 

 

 

CPU Performance

Regular

Disable Monitor Mode @ bootup

N (No) (resulting in Monitor Mode enabled)

HTTP Port Number

80

(1-65535)

 

MTU Size (512 – 1400)

0 (resulting in an operational value of 1400)

 

 

TCP Re-transmission Timeout

500

(500 - 4000) (ms)

 

 

 

Enable alternate MAC

Disabled (OEM use only)

 

 

Ethernet connection type

0 (resulting in auto-negotiation)

 

 

Config Server Port Number

30718

 

 

Automatic Host MAC Detection

Y (Yes)

 

 