7: Setup Mode: Channel Configuration
WiBox® 2100E Device Server User Guide 59
Auto Increment Source Port
Auto increment source port (N) ? _
Y (Yes) auto increment the source port. The WiBox 2100E increments the port n umber used with
each new connection.
Remote IP Address
This is the destination IP address used with an outgoing connection.
Remote IP Address : (000) (000) (000) (000)_
Note: This option does not display when Hostlist is enabled from the ConnectMode
prompt (see Connect Mode on page 52 for more information).
Remote Port
You must set the remote TCP port number for the unit to make outgoing conn ections. This
parameter defines the port number on the target host to which a connect ion is attempted.
Remote Port (0) ? _
To connect an ASCII terminal to a host using the unit for login purposes, us e the remote port
number 23 (Internet standard port number for Telnet services).
Note: This option does not display when Hostlist is enabled from the ConnectMode
prompt (see Connect Mode on page 52 for more information).
DisConnMode
This setting determines the conditions under which the unit will cause a network connection to
terminate. The default setting is 00.
DisConnMode (00) ? _
Notes:
In DisConnMode (Disconnect Mode), Modem Control In either drops the connection or
is ignored.
Note: All bit positions in the table that are blank represent “don’t care” bits for th at
particular option; they can be set to either a 0 or 1 value.