8: Setup Mode: Channel Configuration

b) Response

Character Response

A single character is transmitted to the serial port when there is a change in connection state: C = connected, D = disconnected, N = host unreachable. The IP address of the host connecting to the CoBos device will be provided when you use verbose mode.

This option is overridden when the Active Start Modem Mode or Active Start Host List is in effect. Default setting is Nothing (quiet).

c) Active Startup

No Active Startup

Does not attempt to initiate a connection under any circumstance. Default setting.

 

 

With Any Character

Attempts to connect when any character is received from the serial port.

 

 

With active Modem

Attempts to connect when the Modem Control In input changes from not

Control in

asserted to asserted.

 

 

With a Specific Start

Attempts to connect when it receives a specific start character from the serial port.

Character

The default start character is carriage return.

 

 

Manual Connection

Attempts to connect when directed by a command string received from the serial

 

port. The first character of the command string must be a C (ASCII 0x43), and the

 

last character must be either a carriage return (ASCII 0x0D) or a line feed (0x0A).

 

No blanks or space characters may be in the command string. Between the first

 

and last command string characters must be a full or partial destination IP address

 

and may be a destination port number.

 

The IP address must be in standard decimal-dot notation and may be a partial

 

address, representing the least significant 1, 2, or 3 bytes of the remote IP

 

address. The period is required between each pair of IP address numbers.

 

If present, the port number must follow the IP address, must be presented as a

 

decimal number in the range 1-65535, and must be preceded by a forward slash

 

(ASCII 0x2F). The slash separates the IP address and the port number. If you

 

omit the port number from a command string, the internally stored remote port

 

number starts a connection.

 

If a partial IP address is presented in a command string, it is interpreted to be the

 

least significant bytes of the IP address and uses the internally stored remote IP

 

address to provide the most significant bytes of the IP address. If the IP address

 

entered is 0.0.0.0/0, the device server enters Monitor Mode.

For example, if the remote IP address already configured in the unit is 129.1.2.3, then an example command string would be C3/7. (This would connect to

129.1.2.3and port 7.) You may also use a different ending for the connection string. For example, C50.1/23 would connect you to 129.1.50.1 and port 23.

If an IP address does not follow the first command string character (which is "C"), the subsequent character string is interpreted as the host name and domain to be used in DNS lookup. This character string can include a destination port number as well. The port number can be preceded by either a forward slash (/) or a colon ( : ).

 

Table 8-7 Manual Connection Address Example

 

 

 

Command String

 

Result if remote IP is 129.1.2.3 and remote port is 1234

C121.2.4.5/1

 

Complete override; connection is started with host 121.2.4.5, port 1.

 

 

 

C5

 

Connects to 129.1.2.5, port 1234.

 

 

 

C28.10/12

 

Connects to 129.1.28.10, port 12.

 

 

 