Unit Dimensions −− Inches (mm)

39−1/2

DISCHARGE AIR

 

ELECTRICAL INLETS

35−1/2

 

 

(1003)

 

 

 

 

 

 

 

 

(902)

 

 

 

 

 

 

 

 

37 (940) [−024 THRU −042] 47

 

 

 

 

(1194) [−048 AND −060]

 

 

 

VAPOR LINE

4−7/16

 

 

 

(113)

 

 

 

INLET

 

 

 

 

 

 

 

 

 

LIQUID LINE

18−1/2

 

 

 

INLET

 

 

 

 

 

(470)

 

 

 

 

 

 

 

 

 

 

8 (203)

 

 

 

 

 

 

1 (25)

SIDE VIEW

ACCESS VIEW

UNIT SUPPORT

FEET

16−7/8

(429)

8−3/4

 

(222)

 

3−1/8

30−3/4

(79)

(781)

26−7/8

(683)

3−3/4 (95)

4−5/8

(117)

 

 

 

 

BASE WITH ELONGATED LEGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model Number Identification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XP 17 −0362302

 

Refrigerant Type

 

 

 

 

 

 

 

 

 

 

 

 

 

Minor Revision Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X = R−410A

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230 = 208/230V−1ph−60hz

 

Unit Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P = Heat Pump Outdoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Cooling Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

= 2 tons

 

 

Series

 

 

 

 

 

030

= 2.5 tons

 

 

 

 

 

 

 

 

 

 

036

= 3 tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

= 3.5 tons

 

 

 

 

 

 

 

048

= 4 tons

 

 

 

 

 

 

 

060

= 5 tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 