4026-0XX
Parallel Port Service Check
1.Do a print test to be sure the printer prints correctly.
2.Be sure the printer parallel cable is designed for
3.Be sure the user application is set up correctly. Improper set up can prevent establishing a communication link with the printer.
4.Be sure controller board jumper J3 is located on pins two and three. J3 in this position causes the parallel port
Do the following to enable the
Turn the printer power off.
Place J3 between pins one and two.
Turn the printer power on and run POST.
Run a print test page from the host.
5.If the printer still does not print, return J3 to the original position.
6.If the internal print test page prints correctly, the user application and printer driver is set up correctly and the correct printer par- allel
Paper Feed Service Check
CAUTION: To check the paper feed it may be necessary to run the machine with the covers removed and the top cover interlock dis- abled. If this is necessary, NEVER disable both the top cover inter- lock and the printhead shutter actuator at the same time.
If it is necessary to run the machine to check for paper feed problems, open the top cover and disable the top cover interlock switch. You can feed paper after POST has completed by running the Normal Mode Print Test. To check some of the paper feed for proper operation, it may be necessary to remove the toner cartridge and photoconductor unit assemblies. Do not expose the photoconductor unit to direct sunlight. Keep it covered. The photoconductor will be damaged if exposed to light for any length of time.