Low Voltage Power Supply Service Check
Note: The controller board, HVPS and printhead assembly receive power from the LVPS through the engine board.
If the machine is dead, be sure the controller board is correctly seated in the engine board connector.
Check and reseat all cables.
Dead Printer
| FRU | Action |
|
|
|
1 | Line Voltage | Check the AC line voltage. The voltages should |
|
| be within the following limits: |
|
| 100 V ac (90 V ac - 110 V ac) Japan |
|
| 120 V ac (108 V ac - 132 V ac) U.S. |
|
| 220/230 V ac (207 V ac - 253 V ac) W.T. |
|
|
|
2 | LVPS | The voltage measures approximately +5 V dc |
|
| between |
|
| board. If incorrect, disconnect CN7 on the |
|
| engine board and measure the voltage between |
|
| |
|
| reading should measure approximately +5 V dc. |
|
| If +5 V dc is not present, unplug the printer line |
|
| cord and check fuse F1. If the fuse is open, |
|
| replace the fuse. If the fuse is not open, replace |
|
| the LVPS. |
|
|
|
3 | Engine Board | If +5 V dc is present when CN7 is disconnected |
|
| then disconnect CN2, CN4, CN5, CN9 and |
|
| CN10 from the engine board. Also disconnect |
|
| the controller board and remove the ROM SIMM |
|
| and any optional memory SIMMs. Reconnect |
|
| CN7 and check for +5 V dc. If incorrect, replace |
|
| the engine board. |
|
|
|
4 | Controller | Reinstall the controller board. Check for +5 V dc |
| Board | at |
|
| board. |
|
|
|