4026-0XX
| FRU | Action |
|
|
|
3 | Input Sensor | Check the flag for damage, especially at the |
| Flag | front edge, Be sure the flag moves freely. |
|
| Replace the flag as necessary. |
|
|
|
4 | Input Sensor | Be sure the input sensor is correctly installed |
|
| and the sensor/solenoid cable is properly con- |
|
| nected. |
|
| Disconnect the input sensor cable from the CN3 |
|
| connector on the engine board. The voltage at |
|
| |
|
| dc. If incorrect, replace the engine board. |
|
| If correct, reconnect the input sensor cable at |
|
| CN3. Monitor the voltage at |
|
| the sensor flag in and out. The voltage changes |
|
| from +2 V dc to 0 V dc. If incorrect, check the |
|
| input sensor/solenoid cable continuity. If cable |
|
| continuity is incorrect, replace the paper feed |
|
| frame assembly. If cable continuity is correct, |
|
| replace the following FRUs one at a time in the |
|
| order shown: |
|
| Input Sensor |
|
| Engine Board |
|
|
|