F-8

TROUBLESHOOTING & REPAIR

F-8

 

 

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

FEEDING PROBLEMS

 

 

 

Meter reads low voltage (1-2 VDC),

Local/Remote Switch must be in

1.

See Output Diodes test.

 

and output is extremely low or no

LOCAL position unless Remote

 

 

 

output.

 

Control device is attached to remote

2.

See Capacitor Balance

tests.

 

 

 

receptacle.

 

 

 

 

 

 

 

3.

See Switch Board test.

 

 

 

 

 

4.

See Power Board test.

 

 

 

 

 

5.

Control Board may be defective.

Poor welding, weld settings drift, or

Check welding procedures and weld

1.

Check Mode Switch S2 for dam-

output power is low.

cable connections.

 

age and continuity.

 

 

Check with machine on local con-

 

 

 

 

 

trol.

2.

Check

for continuity

between

 

 

 

Mode Switch S2 and Control

 

Check input voltages and input volt-

 

Board. See Wiring Diagram in

 

age reconnect procedures. See

 

Section G.

 

 

Installation section of this manual.

 

 

 

 

 

 

3.

Check for loose or faulty con-

 

 

 

nections in heavy current-carry-

 

 

 

ing leads (i.e., choke, shunt,

 

 

 

output

bridge, and

output

 

 

 

studs). See wiring diagram in

 

 

 

Section G.

 

4. See Overcurrent Protection Current Trigger Circuit tests.

5. See Control Board test

Welding “too hot”. Actual weld cur-

Check condition of the shunt and

See Step 7 of the Overcurrent

rent is considerably higher than dis-

leads to the Control Board.

Protection Current Trigger test

play indicates.

 

If shunt and leads check OK, possi-

 

 

 

 

ble defective Control Board

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

V300-I