306

275F

L7915

313

J8

PROTECTION

J15

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

311

TEST PROCEDURE

12.Open S4 and Turn Power OFF

13.Move probes to test between leads 306 (+) and 275 (-). (See Figure F.6)

14.Turn Power ON and close S4. If voltage is less than 1 VDC, Protection Board is OK. If voltage is greater than 14 VDC, Protection Board may be defective.See Overvoltage Protection DC Trigger Circuit test, Step 11.