TROUBLESHOOTING & REPAIR

F-36

OVERCURRENT PROTECTION CURRENT TRIGGER TEST (cont.)

FIGURE F.12 - GETTING ACCESS TO CONTROL BOARD

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Perform Input Filter Capacitor Discharge Procedure detailed in this section.

2.Remove front panel from machine to access Control Board.

4.Turn main power ON.

5.Test for 15 VDC between leads 302 and 275D.

a. If 15 VDC is present, test is OK. Go to step 6.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

 

b. If 15 VDC is not present, check Power Board

3. Arrange wires so there is ample room to work on

and leads 302 and 275D for continuity and wire

the board.

breakage.

FIGURE F.13 - CONTROL BOARD TEST POINTS

302

J5

G2527 CONTROL J1

J2

J4

J3

275D

V300-I