F-62

TROUBLESHOOTING & REPAIR

F-62

RETEST AFTER REPAIR

Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced, the machine must be retested.

NOTE: 50 Hz machines may be tested using 60 Hz power.

INPUT IDLE AMPS AND IDLE WATTS

 

Input

 

Single Phase

 

 

 

Three Phase

 

 

 

Volts/Hertz

 

Max. Amps

 

Max. Watts

 

Max. Amps

 

Max. Watts

 

 

220/50 or 60

2.75

 

 

425

 

 

2.75

 

 

 

425

 

 

230/60

3.00

 

 

450

 

 

3.00

 

 

 

450

 

 

440/50 or 60

1.38

 

 

425

 

 

 

 

 

 

 

 

 

 

460/60

1.50

 

 

450

 

 

 

 

 

 

 

 

 

 

380/50 or 60

1.67

 

 

425

 

 

 

 

 

 

 

 

 

 

575/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OCV at rated INPUT: V300-PRO,V300-I

 

 

 

60-75V

 

 

 

 

MAXIMUM ACCEPTABLE OUTPUT AMPS (AT MINIMUM OUTPUT SETTINGS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. (Max. acceptable), all machines:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC modes

 

12A @ 10V.

 

(GTAW, SOFT, CRISP)

 

 

 

 

 

 

CV modes

 

20A @ 19V.

 

(FCAW, GMAW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT MINIMUM ACCEPTABLE VOLTS (AT MAXIMUM OUTPUT SETTINGS,

 

 

 

 

WITH FULL LOAD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. Acceptable,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. — All Modes

 

V300-I

 

 

 

V300-PRO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 phase @ 200A

 

380V

 

 

220/440V

 

 

208V

 

230/460V

575V

 

 

 

 

 

38V

 

 

38V

 

36V

 

 

3 phase @ 300A

 

32V

 

36V

 

34V

 

38V

 

36V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUXILIARY TRANSFORMER — 50 Hz or 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST POINTS

 

 

 

 

RANGE

 

 

18 VAC winding to Power Board J7 pins 5 and 6 Welding

 

 

 

 

17-20 VAC

 

 

terminals sw. remote

 

 

 

 

 

 

 

 

 

 

 

24 VAC winding to Control Board J2 pin 4 to lead 212

 

 

 

 

23-26.5 VAC

 

 

STANDARD CODES: (Test at Amphenol)

 

 

 

 

 

 

 

 

24 VAC without load, measure across pins C and D

 

 

 

 

22-25 VAC

 

 

42 VAC without load, measure across pins I and K

 

 

 

 

39-44 VAC

 

 

115 VAC without load, measure across pins A and J

 

 

 

 

109-120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V300-I