F-19

TROUBLESHOOTING & REPAIR

F-19

 

 

 

PROTECTION BOARD OUTPUT TEST(cont.)

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

TEST PROCEDURE

8.With power OFF, disconnect J8 and attach voltage probes into back of wire harness lead junction block (J8). See Figure F.5.

Insert probes into back of the connection cavities for leads 313 (-) and 311 (+) of Protection Board. Make sure contact is made with conductor materi- al.

NOTE: Right-angle, thin-gauge probes are best for this test.

With probes attached, plug the (J8) block into the PC board.

9.Turn main power ON.

10.Move Output Terminal Switch S4 to ON position on Control Panel.

11.Test for less than 1 VDC between leads 313 (-) and 311 (+).

a.If less than 1 VDC is measured, test is OK and Protection Board is functioning properly.

b.If more than 5 VDC is measured, go to Static Capacitor Balance Test.

NOTE: During voltage test, be cautious when posi- tioning loose components to avoid shorts and dam- age to equipment.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

FIGURE F.5 - INSERTING PROBES

L7915

PROTECTION

 

313

306

J8

J15

 

275F

311

V300-I

Page 49
Image 49