Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-27

 

TROUBLESHOOTING & REPAIR

F-27

 

 

 

 

 

 

 

 

 

SWITCH BOARD TEST (CONT.)

 

 

 

 

 

 

TABLE F.2

 

 

 

 

 

 

SWITCH BOARD RESISTANCE CHECKS

 

 

 

 

 

 

 

 

 

Apply Positive Apply Negative

 

 

 

 

 

Test Probe to

Test Probe to

 

 

 

 

 

Terminal

Terminal

Test Result

Conclusion

Repair Action

Next Procedure

Notes

 

1/8

12

Greater than

OK

None

Continue

 

 

 

 

1K ohm

 

 

 

 

 

 

 

Less than

Shorted

Replace both

Snubber Test

 

 

 

 

100 ohms

 

Switch Boards

 

 

 

 

 

 

 

 

 

 

 

12

1/8

Less than

OK

None

Continue

 

 

 

 

100 ohms

 

 

 

 

 

 

 

Greater than

Open

Replace both

Snubber Test

 

 

 

 

1K ohm

 

Switch Boards

 

 

 

 

 

 

 

 

 

 

 

9

4/5

Greater than

OK

None

Continue

 

 

 

 

1K ohm

 

 

 

 

 

 

 

Less than

Shorted

Replace both

Snubber Test

 

 

 

 

100 ohms

 

Switch Boards

 

 

 

 

 

 

 

 

 

 

 

4/5

9

Less than

OK

None

Continue

 

 

 

 

100 ohms

 

 

 

 

 

 

 

Greater than

Open

Replace both

Snubber Test

 

 

 

 

1K ohm

 

Switch Boards

 

 

 

 

 

 

 

 

 

 

 

1/8

9

Less than

OK

None

Continue

 

 

 

 

100 ohms

 

 

 

 

 

 

 

Greater than

Open

Replace both

Snubber Test

 

 

 

 

1K ohm

 

Switch Boards

 

 

 

 

 

 

 

 

 

 

 

9

1/8

Greater than

OK

None

Continue

 

 

 

 

1K ohm

 

 

 

 

 

 

 

Less than

Shorted

Replace both

Snubber Test

 

 

 

 

100 ohms

 

Switch Boards

 

 

 

12

4/5

Less than

OK

None

Continue

 

 

 

 

100 ohms

 

 

 

 

 

 

 

Greater than

Open

Replace both

Snubber Test

 

 

 

 

1K ohm

 

Switch Boards

 

 

 

 

 

 

 

 

 

 

 

4/5

12

Greater than

OK

None

Continue

 

 

 

 

1K ohm

 

 

 

 

 

 

 

Less than

Shorted

Replace both

Snubber Test

 

 

 

 

100 ohms

 

Switch Boards

 

 

 

 

 

 

 

 

 

 

 

NOTE: K ohm = ohm reading multiplied by 1000.

NOTE: Always make sure that Switch Boards are changed in matched pairs. Never mix an old style (different part number) Switch Board with a newer style.

V300-I

Page 57
Image 57
Lincoln Electric SVM101-B service manual Switch Board Test