V300-I
TROUBLESHOOTING & REPAIR
7. Test for 0 VDC between leads 311 and 313 on
Protection Board.
a. If 0-1 VDC is present, the Protection Board is
OK. Go to step 8.
b. If 15 VDC is present, go to step 11.
F-40 F-40
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
OVERVOLTAGE PROTECTION DC TRIGGER CIRCUIT TEST (cont.)
FIGURE F.17 — PROTECTION BOARD TEST POINT
PROTECTION
L7915
306
313
275F
311
J8 J15