Lincoln Electric SVM188-A service manual Meaning of Graphical Symbol for Ground CON- Nection

Models: SVM188-A

1 97
Download 97 pages 32.48 Kb
Page 23
Image 23

B-5

OPERATION

B-5

Return to Section TOC

Return to Section TOC

MEANING OF GRAPHICAL SYMBOLS ON RATING PLATE (LOCATED ON CASE BACK)

Designates welder complies with National Electrical Manufacturers NEMA EW 1 (100%) Association requirements EW 1 Class I with 100% duty cycle at

600Amps output.

Three Phase Input Power

3 Phase transformer with recti- fied DC output

Line Connection

MEANING OF GRAPHICAL SYMBOL FOR GROUND CON- NECTION

Signifies the equipment connection point for the protective earth ground

CONTROLS AND SETTINGS

All operator controls and adjustments are located on the Case Front Assembly of the DC-600. See Figure B.1 for the location of each control.

5

3

6

8

9

4

 

 

 

 

 

7

 

5

6

 

1

 

4

 

 

 

 

 

7

 

 

 

 

 

 

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

R

NRTL/C

Gas Metal Arc Welding (GMAW)

Flux Cored Arc Welding (FCAW)

Shielded Metal Arc Welding (SMAW)

Submerged Arc Welding (SAW)

Designates welder complies with both Underwriters Laboratories (UL) standards and Canadian Standards Association (CSA) standards. (60 Hertz Models)

3

 

8

 

2

 

9

 

1

 

10

 

DC-600

2

 

 

11

 

10

12

 

 

13

FIGURE B.1 - CONTROL PANEL KEYS

1.Input POWER ON/OFF Switch

This toggle switch turns the machine on or off.

Putting the switch in the ON “

” position ener-

gizes the machine’s input contactor applying input power to the machine. Switching the switch to the

OFF “ ” position de-energizes the input con- tactor.

2.POWER Light

When the POWER switch is in the ON position the machine’s white POWER light will illuminate. If the input contactor de-energizes the machine in an abnormal situation the pilot light will still illuminate. In this situation it may be necessary to reset the machine by switching the POWER switch to the OFF and then to the ON position. (See Overload, Overcurrent, and Fault Protection Section)

DC-600

Page 23
Image 23