TROUBLESHOOTING AND REPAIR

F-23

MAIN TRANSFORMER VOLTAGE TEST (continued)

FIGURE F.9 – TRANSFORMER SECONDARIES

A

A

A

SECONDARY LEADS

COMMON BUSS

(6 PLACES)

 

 

PROCEDURE

 

 

9. Test with an AC voltmeter for approximately 55 VAC

NOTE: All of the secondary voltages will vary if the

from each of the six main transformer secondary

input line voltages vary. If any one or more of the volt-

leads to the common bus connected to the output

age checks are incorrect, check for loose or faulty con-

choke. See Figure F.9.

 

nections. See the Wiring Diagram. If the leads and

 

 

connections are OK, the main transformer may be

faulty.

FIGURE F.10 – AUXILIARY VOLTAGES

 

5

6

 

4

 

 

 

7

 

3

 

RECEPTACLE

 

8

2

 

 

 

9

 

1

10

 

 

TS 2

 

DC-600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21+ 21- 41 4 2

31 32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROCEDURE

Return to Section TOC

Return to Master TOC

10.Test for 120 VAC between leads #31 and #32 on terminal strip TS-2. See Figure F.10. 120 VAC should also be present at the receptacle. If the cor- rect voltage is not present, make sure the 20 amp circuit breaker is not tripped or faulty. Also check the wiring between the main transformer, the termi- nal strip, the circuit breaker and the receptacle. See the Wiring Diagram.

12.Test for 42 VAC between leads #41 and #2 on the terminal strip. See Figure F.10. If the correct volt- age is not present, make sure the 10 amp circuit breaker is not tripped or faulty. Also check the wiring between the main transformer, the terminal strip, and the circuit breaker. See the Wiring Diagram.

DC-600

Page 63