F-8

TROUBLESHOOTING AND REPAIR

 

 

F-8

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

Poor arc starting when the DC600 is

1.

Make sure the proper welding

1.

Check the connections from the

in the CV Sub-Arc or CV Innershield

 

procedures are being used.

 

shunt to the Control Board

Modes.

 

 

(wire feed speed, arc voltage

 

(leads 210 and 215). When weld

 

 

 

and wire size)

 

current is present there should

 

 

2. Check weld cables for loose or

 

be a millivolt signal at the board

 

 

 

(6.25mv/100 amps).

 

 

 

 

faulty connections.

 

 

 

 

 

 

 

 

 

2. Perform the Firing Board Test.

 

 

 

 

3.

Perform

the

SCR

Output

 

 

 

 

 

Bridge Test.

 

 

 

 

 

 

4. The Control

Board

may be

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

 

Poor arc characteristics in all

1.

Check for the correct input volt-

1.

Check the Mode Switch (SW4)

processes.

 

 

ages on the three phase input

 

and the associated wiring for

 

 

 

lines at the DC600.

 

loose or faulty connections. See

 

 

 

 

 

the Wiring Diagram.

 

 

 

2. Make sure the proper welding

 

 

 

 

 

 

 

 

procedures are being used (wire

2.

Check the voltage at the shunt

 

 

 

feed speed, arc voltage and wire

 

(leads 210 and 215). When weld

 

 

 

size).

 

current is present there should

 

 

 

 

 

be a millivolt signal at the board

 

 

3.

Check the welding cables for

 

(6.25mv/100 amps). If not cor-

 

 

 

loose or faulty connections.

 

rect, the shunt may be defective

 

 

 

 

3. Perform the Firing Board Test.

 

 

 

 

4.

Perform

the

SCR

Output

 

 

 

 

 

Bridge test.

 

 

 

 

 

 

5. The Control

Board

may be

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

DC-600

Page 48