F-4

TROUBLESHOOTING AND REPAIR

 

 

F-4

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

The Machine is dead - The Input

1.

Check

for blown

or missing

1.

The ON/OFF Switch

(S1) may

contactor does not operate.

 

fuses in input lines.

 

 

be faulty

 

 

 

 

 

2. Check the three phase input line

2.

The

Control Transformer

(T2)

 

 

 

voltage

at the

machine. The

 

may

be faulty.

Perform

the

 

 

 

input voltage must match the

 

Control Transformer Test.

 

 

 

 

rating

plate

and

reconnect

 

 

 

 

 

 

 

 

 

panel.

 

 

 

3.

The primary or secondary ther-

 

 

 

 

 

 

 

 

mostats may be open. Check or

 

 

 

 

 

 

 

 

replace. Also check the associ-

 

 

 

 

 

 

 

 

ated wiring. See the Wiring

 

 

 

 

 

 

 

 

Diagram.

 

 

 

 

 

 

 

 

 

 

4.

The pilot relay (CR2) may be

 

 

 

 

 

 

 

 

faulty. Check or replace.

 

 

 

 

 

 

 

 

5.

The input contactor coil may be

 

 

 

 

 

 

 

 

open.

 

 

 

 

 

 

 

 

 

 

6.

The Control Board may be

 

 

 

 

 

 

 

 

faulty. Perform

the

Control

 

 

 

 

 

 

 

 

Board Test.

 

 

 

 

 

 

 

 

Input contactor (CR1) chatters.

1.

The input line voltage may be

1.

The pilot relay (CR2) may have

 

 

 

low. Check all three phases.

 

bad contacts. Check or replace

 

 

 

 

 

 

 

 

relay.

 

 

 

 

 

2. Make sure input line voltage

2.

Check for loose or faulty wiring

 

 

 

matches machine rating and the

 

 

 

reconnect panel is

connected

 

between pilot relay (CR2) and

 

 

 

correctly for the line voltage

 

input contactor (CR1) coil con-

 

 

 

 

 

 

 

 

nections.See Wiring Diagram.

 

 

 

 

 

 

 

3.

The input contactor (CR1) may

 

 

 

 

 

 

 

 

be faulty.-Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

DC-600

Page 44
Image 44