Lincoln Electric SVM188-A service manual J1,Pin2. See Wiring Diagram

Models: SVM188-A

1 97
Download 97 pages 32.48 Kb
Page 47
Image 47

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-7

TROUBLESHOOTING AND REPAIR

 

 

 

 

F-7

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

Machine has maximum weld output

1.

If remote control is being used

1.

Check

the

LOCAL/REMOTE

and no control.

 

 

set LOCALl/REMOTE SWITCH

 

Switch (SW3)

and

associated

 

 

 

(SW3) to ‘LOCAL’ position and

 

wiring.

 

 

 

 

 

 

 

 

try to control weld output using

 

 

 

 

 

 

 

 

 

 

the Output Control

2.

Check

feedback leads #222

 

 

 

Potentiometer (R1) at the

 

(negative

output

terminal),

 

 

 

DC600. If the problem is solved

 

#215, and

#210 (output shunt)

 

 

 

check the remote control unit

 

for loose or faulty connections.

 

 

 

(or wire feeder) and associated

 

See Wiring Diagram.

 

 

 

 

control cable.

 

 

 

 

 

 

 

 

 

 

 

3. Check the #75 lead for continu-

 

 

 

 

 

ity (zero ohms) from the Output

 

 

 

 

 

Control

Potentiometer

(R1) to

 

 

 

 

 

the control board

connector

 

 

 

 

 

J1,Pin2. See Wiring Diagram.

 

 

 

 

4.

Possible

defective

 

Control

 

 

 

 

 

Board or Firing Board. See the

 

 

 

 

 

PC Board

Troubleshooting

 

 

 

 

 

Guide.

 

 

 

 

 

 

 

 

 

5.

Perform

the

SCR

Output

 

 

 

 

 

Bridge Test.

 

 

 

 

 

 

 

 

 

 

 

Machine has minimum output and

1.

If a remote control unit is NOT

1.

Check

the

Output

Control

no control.

 

 

connected to the DC-600, the

 

Potentiometer (R1) and associ-

 

 

 

LOCAL/REMOTE Switch must

 

ated wiring.

 

 

 

 

 

 

 

be in the "LOCAL" position.

 

 

 

 

 

 

 

 

 

 

 

2.

Check

the

LOCAL/REMOTE

 

 

2. If a remote control cable is con-

 

Switch (SW3), the Weld Mode

 

 

 

nected, the control leads may

 

Switch (SW4)

and

associated

 

 

 

be "shorted" to the positive weld

 

wiring.

 

 

 

 

 

 

 

 

output.

 

 

 

 

 

 

 

 

 

 

 

3.

Perform

the

Control

Board

 

 

3.

Make certain the three phase

 

Test.

 

 

 

 

 

 

 

 

input voltage is correct and

 

 

 

 

 

 

 

 

 

 

matches the machine rating and

4.

Perform the Firing Board Test.

 

 

 

the reconnect panel.

 

 

 

 

 

 

 

 

 

 

 

5.

Perform

the

SCR

Output

 

 

 

 

 

Bridge Test.

 

 

 

 

 

 

 

6. Perform the Main Transformer

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

DC-600

Page 47
Image 47