ACCESSORIES

C-2

Return to Section TOC

TOC

WIRE FEEDERS AND TRACTORS

The DC-600 can be used to power any of the following Lincoln Wire Feeders and Tractors:

Semi-Automatic Wire Feeders:

DH-10

LN-9

LN-7

LN-9 GMA

LN-7 GMA

LN-23P

LN-742

LN-25

LN-8

LN-10

Automatic Wire Feeders:

NA-3NA-5R

NA-5

Tractors:

LT-7LT-56

Undercarriages (K817P, K842)

For easy moving of the machine, optional undercar- riages are available with polyolefin wheels (K817P) or a platform undercarriage (K842) with mountings for two gas cylinders at rear of welder.

Paralleling Kit (K1611-1)

Permits paralleling of two DC-600's for welding cur- rents of up to 1200 amps, 100% duty cycle.

Tig Module (K930-2)

Portable high frequency generator for AC/DC TIG welding.

FACTORY OR FIELD INSTALLED OPTIONS

Return to Section

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

FIELD INSTALLED OPTIONS

Remote Output Control (K775 or K857 with K864 Adapter)

An optional “remote out control” is available. The K775 is the same remote control that is used on other Lincoln power sources. The K775 consist of a control box with 28 feet (8.5mm) of four conductor cable. This connects to terminals 75,76, and 77 on the terminal strip (T.S.1) and the case grounding screw so marked

with the symbol “ ” on the machine. These termi- nals are located behind the hinged cover on the case front. This control will give the same control as the out- put control on the machine.

The K857 is similar to the K775, except the K857 has a 6-pin MS-style connector. The K857 requires a K864 adapter cable which connects to the 14-pin connector on the case front.

Remote Control Adapter Cable (K864)

S T R A I G H T P L U G ( 1 4 P I N )

 

 

 

 

 

 

 

 

 

C A B L E R E C E P T A C L E ( 6 S O C K E T )

 

 

 

 

 

 

 

 

 

TO P O W E R S O U R C E

 

 

 

 

 

 

 

 

 

T O : K 8 5 7 R E M O T E C O N T R O L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C A B L E R E C E P T A C L E ( 1 4 S O C K E T )

T O : L N - 7 W I R E F E E D E R S

A "V" cable 12" (.30 m) long to connect a K857 Remote Control (6-pin connector) with an LN-7 wire-feeder (14- pin connector) and the machine (14-pin connector). If a remote control is used alone the wire-feeder connec- tion is then not used.

Multi-Process Switch (K804-1)

The MULTI-PROCESS SWITCH gives you the ability to:

Switch between "stick welding or air/carbon arc cut- ting" and using a semi-automatic or automatic wire feeder.

Change the polarity of a semi-automatic or auto- matic wire feeder without changing any electrical cable connections.

See Figure C.1

 

+

-

STICK OR

AIR

 

CARBON

 

ARC

+

WIRE

STICK OR

FEEDER

AIR/CARBON

CABLES

ARC CABLES

FIGURE C.1 - MULTI-PROCESS SWITCH