B-4

OPERATION

B-4

WELDING CAPABILITY

The DC-600 has the following Output and Duty Cycle based on operation for a 10 minute period:

600 Amps, 44 Volts at 100%

680 Amps, 44 Volts at 60%

750 Amps, 44 Volts at 50%

MEANINGS OF GRAPHICAL SYMBOLS ON CASE FRONT

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Input POWER ON/OFF Switch

SYMBOLMEANING

ON

OFF

INPUT POWER

Pilot Light

Input power on when light is illuminated

(except for abnormal conditions). Always indicates POWER ON/OFF switch is in ON position.

OUTPUT CONTROL

OUTPUT VOLTAGE

AND CURRENT

Clockwise Increase of Output

Voltage and Current

LOCAL/REMOTE Switch

SYMBOLMEANING

Control Of Output Voltage and

Current is Via DC-600's Control Dial

Remote Control of Output Voltage

and Current

MODE Switch

CCSTICK: Shielded Metal Arc Welding (SMAW), this switch

position is also used for Air Carbon Arc Cutting (AAC)

CV SUBMERGED ARC:

Constant Voltage Submerged

Arc Welding (SAW)

CV INNERSHIELD: Flux Cored Arc Welding (FCAW), this switch position is also used for Gas Metal Arc Welding (GMAW).

Output Terminal Connections

Positive Output Terminal

Negative Output Terminal

WARNING Identification

TOC

TOC

TERMINALS ON/REMOTE Switch

OUTPUT TERMINALS

ENERGIZED

Warning Identification

Return to Section

Return to Master

Circuit Breaker

Remote Control of Output Terminals

Circuit Breaker (two breakers: 15A

(Energized or Non-Energized)

for 115V circuit and 10A for 42V

 

circuit)

DC-600

 

Page 22
Image 22
Lincoln Electric SVM188-A service manual Welding Capability, Meanings of Graphical Symbols on Case Front, OFF Input Power