Return to Section TOC
Return to Master TOC
OPERATION |
WELDING CAPABILITY
The
600 Amps, 44 Volts at 100%
680 Amps, 44 Volts at 60%
750 Amps, 44 Volts at 50%
MEANINGS OF GRAPHICAL SYMBOLS ON CASE FRONT
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Input POWER ON/OFF Switch
SYMBOLMEANING
ON
OFF
INPUT POWER
Pilot Light
Input power on when light is illuminated
(except for abnormal conditions). Always indicates POWER ON/OFF switch is in ON position.
OUTPUT CONTROL
OUTPUT VOLTAGE
AND CURRENT
Clockwise Increase of Output
Voltage and Current
LOCAL/REMOTE Switch
SYMBOLMEANING
Control Of Output Voltage and
Current is Via
Remote Control of Output Voltage
and Current
MODE Switch
CCSTICK: Shielded Metal Arc Welding (SMAW), this switch
position is also used for Air Carbon Arc Cutting (AAC)
CV SUBMERGED ARC:
Constant Voltage Submerged
Arc Welding (SAW)
CV INNERSHIELD: Flux Cored Arc Welding (FCAW), this switch position is also used for Gas Metal Arc Welding (GMAW).
Output Terminal Connections
Positive Output Terminal
Negative Output Terminal
WARNING Identification
TOC
TOC
TERMINALS ON/REMOTE Switch
OUTPUT TERMINALS
ENERGIZED
Warning Identification
Return to Section
Return to Master
Circuit Breaker | |
Remote Control of Output Terminals | Circuit Breaker (two breakers: 15A |
(Energized or | for 115V circuit and 10A for 42V |
| circuit) |
|