Maintenance and Troubleshooting
Unipro 3.5
Rev. 8.00
November 30, 1995
communications, and is
always in receive mode
unless responding to a
question.
"X" Protocol
The "X" protocol software
involves a Parameter Table,
a Program Run Buffer, a
Program Edit Buffer, and a
Serial I/O Program Buffer.
The UNIPRO can be
written to using a
"1TXparameternumber$da
ta" format. This entry
would place the data value
in the proper location as
determined by the
parameter number. Any
parameter can be read back
from the UNIPRO using the
following format
"1Txparameternumber".
Therefore, to write a value
to the UNIPRO for a
specific parameter use an
"X" or to read a specific
parameter from the
UNIPRO, use an "x".
All of the parameters are
listed below along with a
short description. The
numbers in the parenthesis
are in Hexadecimal.*