8399 N/B Maintenance

5.3 VIA VT8235CD South Bridge(8)

General Purpose Outputs

Signal Name

Pin #

I/O

GPO0 (VSUS33)

AA3

O

GPO1 / SUSA#

AA2

O

(VSUS33)

 

 

GPO2 / SUSB#

AD3

O

(VSUS33)

 

 

GPO3 /

Y3

O

SUSST1#

 

 

(VSUS33)

 

 

GPO4 / SUSCLK

AB3

O

(VSUS33)

 

 

GPO5 /

AC7

O

CPUSTP#

 

 

GPO6 / PCISTP#

AD6

O

GPO7 / GNT5#

R2

O

GPO12 / GPI12 /

D4

O

INTE#

 

 

GPO13 / GPI13 /

E4

O

INTF#

 

 

GPO14 / GPI14 /

A3

O

INTG#

 

 

GPO15 / GPI15 /

B3

O

INTH#

 

 

GPO20 / GPI20 /

U1

OD

ACSDIN2 /

 

 

PCS0#

 

 

GPO21 / GPI21 /

V3

OD

ACSDIN3 /

 

 

PCS1#

 

 

/SLPBTN#

 

 

GPO22 / GPI22 /

R22

OD

GHI#

 

 

GPO23 / GPI23 /

P21

OD

DPSLP#

 

 

GPO26 / GPI26 /

AD1

OD

SMBDT2

 

 

(VSUS33ƒ)

 

 

GPO27 / GPI27 /

AC3

OD

SMBCK2

 

 

(VSUS33ƒ)

 

 

 

General Purpose Outputs (Continued)

Signal Description

 

 

Signal Name

Pin #

I/O

Signal Description

General Purpose Output 0.

 

 

GPO28 / GPI28

AC8

OD

General Purpose Output 28. RxE5[3] = 1, PMIO 4C[28]=1

General Purpose Output 1. Rx94[2] = 1

 

 

GPO29 / GPI29 /

AB9

OD

General Purpose Output 29. RxE5[3] = 1, PMIO 4C[29]=1

General Purpose Output 2. Rx94[3] = 1

 

 

VRDSLP

 

 

 

 

 

Note: The output state for each of the above general purpose outputs is selectable via Power

 

 

 

Management I/O registers Rx4C-48

 

General Purpose Output 3. Rx94[4] = 1

 

 

Note: Default pin functions are underlined in the table above.

General Purpose Output 13. RxE4[4]=1, 5B[1]=0

 

Documentby VSUS33.

General Purpose Output 4. Rx95[1] = 1

 

 

 

 

 

 

General Purpose Output 5. RxE4[0] = 1

 

 

Power Manage ent and Event Detection

General Purpose Output 6. RxE4[1] = 1

 

 

Signal Name

Pin #

I/O

Signal Description

MiTac

 

PWRBTN#

AD2

I

Power Button. Used by the Power Management subsystem

General Purpose Output 7. RxE4[2] = 0

Secret

 

 

to monitor an external

General Purpose Output 12. RxE4[4]=1, 5B[1]=0

 

 

 

 

 

system on/off button or switch. Internal logic powered

Confidential

SLPBTN# /

V3

I

Sleep Button. Used by the Power Management subsystem

General Purpose Output 14. RxE4[4]=1, 5B[1]=0

 

 

GPIO21/

 

 

to monitor an external sleepbutton or switch. RxE4[6] = 1,

 

 

ACSDIN3 /

 

 

80[6] = 1, E5[2] = 0 and PMIO Rx4C[21] = 1

 

 

 

 

 

General Purpose Output 15. RxE4[4]=1, 5B[1]=0

 

 

PCS1#

 

 

Resume Reset. Resets the internal logic connected to the

 

 

RSMRST#

AD4

I

 

 

 

General Purpose Output 20. RxE4[6]=1, E5[1]=0

 

 

 

 

 

VSUS33 power plane and

 

 

 

 

 

also resets portions of the internal RTC logic. Internal logic

 

 

 

EXTSMI# /

 

 

powered by VBAT.

General Purpose Output 21. RxE4[6]=1, E5[2]=0

 

 

AA1

IOD

External System Management Interrupt. When enabled

 

 

GPI2

 

 

to allow it, a falling edge on

 

 

 

 

 

 

this input causes an SMI# to be generated to the CPU to

 

 

 

 

 

 

enter SMI mode. (10K PU to

General Purpose Output 22. RxE5[3]=1, PMIO 4C[22]=1

 

 

 

 

 

VSUS33 if not used) (3.3V only)

 

 

PME#

W4

I

Power Management Event. (10K PU to VSUS33 if not

General Purpose Output 23. RxE5[3]=1, PMIO 4C[23]=1

 

 

 

 

 

used)

 

 

SMBALRT#

AB1

I

SMB Alert. When programmed to allow it (SMB I/O

General Purpose Output 26. Rx95[2] = 1, 95[3] = 1

 

 

 

 

 

Rx8[3]=1), assertion generates

 

 

 

 

 

an IRQ, SMI, or power management event. (10K PU to

VSUS33 if not used)

General Purpose Output 27. Rx95[2] = 1, 95[3] = 1

87