9.Press the ENTER button.
•The background of the setting item turns red and flashes.
10. Press the JOG , buttons to display the desired setting and then press the ENTER button.
• The setting item is determined and flashing stops.
11. Press the JOG , buttons to move the cursor to “EXECUTE” and then press the ENTER button.
•The <RECORD SETTING> screen appears.
•This menu is used to set the recording interval and recording picture quality of normal recording and alarm recording corresponding to each camera numbers.
<RECORD SETTING> | |||
NO | PPS | GRADE | |
>>1 | 12.5P | SUPER 12.5P | SUPER |
2 | SUPER | SUPER | |
3 | SUPER | SUPER | |
4 | SUPER 12.5P | SUPER | |
ALARM TYPE | ALARM CH | ||
|
<ESTD REC> 1D11H55M
PRESS POWER BUTTON TO EXIT
Set “BOOT UP DELAY” with enough time to accomodate the recognition time of attached HDD.
When setting timer recording in the <TIMER PROGRAM SETTINGS> screen and setting the “BOOT UP DELAY” with 30 seconds or more, the recording start time delays for the amount of time exceeds 30 seconds in the
1.Turn on the MAIN switch on the rear panel and wait until the ACCESS indicator turns off. Make sure that the POWER button on the front panel is turned off. While pressing the JOG button, press the POWER button on the front panel.
•The <INITIALIZATION> screen appears.
•POWER button operation is not accepted while the ACCESS indicator is flashing. Press the POWER button after the indicator turns off.
2.Press the JOG ,
buttons to move the cursor to “BOOT UP DELAY” and then press the ENTER button.
•The background of the setting item turns red and flashes.
ENGLISH
Depending on the number of connected cameras and the value of “RECORDING CYCLE,” the most suitable setting of the “PPS,”
12.When the setting is completed, press the POWER button.
•“SETTING UP...” is displayed on the screen, and the unit
■INITIALIZATION
This menu is used to set HDD SETTING and to initialize the HDD.
♦HDD SETTING
The HDD SETTING can be set to NORMAL, MIRRORING (simultaneous recording of the 2 HDDs), or PARTITION (an independent partition for alarm recording is set within
the total HDD memory). ( see pages 69 and 70 for “MIRRORING” and “PARTITION”)
<INITIALIZATION> | NORMAL |
>>HDD SETTING | |
30S | |
BOOT UP DELAY | |
| |
POWER OFF |
|
INITIALIZATION |
|
| |
| |
|
ALL DATA WILL BE ERASED
WHEN PROCEED INITIALIZATION
♦BOOT UP DELAY
The unit accesses the attached HDD when the power is turned on. Depending on the HDD attached, it may take a long time to be accessed. You do not have to change the setting when this unit recognizes the attached HDD while the BOOT UP DELAY is set to the default setting.
Setting of BOOT UP DELAY (default: “30S”) “10S,” “11S,” • • • • • “30S,” • • • • • “58S,” “59S”
When you do not change the setting, select “POWER OFF.”
3.Press the JOG ,
buttons to display the desired setting and then press the ENTER button.
•The setting item is determined and flashing stops.
4.Press the JOG ,
buttons to select “POWER OFF” and then press the ENTER button.
•The unit turns off.
5.Press the POWER button on the front panel.
•When the amount of time set for BOOT UP DELAY is passed, the unit starts accessing the attached HDD.
•Confirm that the attached HDD is recognized correctly.
♦HDD RECONSTRUCTION
This unit automatically detects the HDD connected to the unit when the POWER button on the front panel is pressed to turn on the unit. When the HDD is connected, added, or deleted, excecute the HDD reconstruction.
<HDD RECONSTRUCTION>
A:HDD(120GB)
B:HDD(120GB)
>>POWER OFF
RECONSTRUCTION
1.Press the POWER button on the front panel.
•“SETTING UP...” is displayed on the screen, and the unit
2.Press the JOG ,
buttons to move the cursor to “RECONSTRUCTION” and then press the ENTER button.
•“SETTING UP...” is displayed on the screen, and the unit
To exit <HDD RECONSTRUCTION> screen without reconstructing the HDD, select “POWER OFF.”
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Initial settings
21