REAR TERMINAL SETTINGS

MODE OUT 1 to MODE OUT 5

These items are used to output the status of this unit from the MODE OUT terminals on the rear panel. There are 5 MODE OUT terminals. Set output type for each terminal individually.

<REAR

TERMINAL SETTINGS>￿

OFF￿

>>MODE

OUT

1

 

MODE

OUT

2

 

OFF￿

MODE

OUT

3

 

OFF￿

MODE

OUT

4

 

OFF￿

MODE

OUT

5

 

OFF￿

KEY SOUND

 

 

ON￿

BUZZER

 

 

OFF￿

REMAIN HDD

MAIN-10%

CALL OUT SETTINGS￿

 

10M

EMERGENCY REC DURATION

3.To set other terminals, repeat step 2.

4.Press the CLEAR button or the SET UP button.

KEY SOUND

This item is used to make button sounds when using the operational buttons.

 

 

 

 

 

 

<REAR

TERMINAL SETTINGS>￿

OFF￿

MODE

OUT

1

 

MODE

OUT

2

 

OFF￿

MODE

OUT

3

 

OFF￿

MODE

OUT

4

 

OFF￿

MODE

OUT

5

 

OFF￿

>>KEY SOUND

 

 

ON￿

BUZZER

 

 

OFF￿

REMAIN HDD

MAIN-10%

CALL OUT SETTINGS￿

 

10M

EMERGENCY REC DURATION

 

 

 

 

 

 

ENGLISH

Setting (default: “OFF”)

“REC”: Outputs signals during recording.

“PLAY”: Outputs signals during playback.

“REMAIN”: Outputs signals when the remaining HDD capacity reaches the value specified in “REMAIN HDD.”

“POWER”: Outputs signals when the power of the unit turns on.

“MOTION1” to “MOTION4”: Outputs the signal from the specified MODE OUT terminal when detecting motion by a specified camera number. For example, when you set MODE OUT 1 to MOTION 1, the signal is output from the MODE OUT 1 terminal when detecting motion by the camera number 1. Furthermore, the last input of the motion detection maintained for 2 seconds.

“ALARM”: Outputs signals during alarm recording.

“LAN”: Controls ON/OFF of the terminal set to this item via PC by using the specified application.

“CALL OUT”: Outputs CALL OUT signal when the error occurs to the unit. Refer to the table on page 81.

OFF”: Does not output signal.

Remaining warning from MODE OUT is output only during recording.

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } Select “REAR TERMINAL SETTINGS” screen.

2.For the desired terminal (from MODE OUT 1 to MODE OUT 5), display the desired setting and then determine such setting.

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } Select “KEY SOUND” in the <REAR TERMINAL SETTINGS> screen. Display the desired setting and determine such setting.

2.Press the CLEAR button or the SET UP button.

BUZZER

This item is used for a buzzer to sound when the remaining HDD capacity reaches the value set in “REMAIN HDD” of the <REAR TERMINAL SETTINGS> screen. Other than the above, it is possible to set the buzzer to sound when starting alarm recording or emergency recording, or when a warning is displayed.

 

 

 

 

 

 

<REAR

TERMINAL SETTINGS>￿

OFF￿

MODE

OUT

1

 

MODE

OUT

2

 

OFF￿

MODE

OUT

3

 

OFF￿

MODE

OUT

4

 

OFF￿

MODE

OUT

5

 

OFF￿

KEY SOUND

 

 

ON￿

>>BUZZER

 

 

OFF￿

REMAIN HDD

MAIN-10%

CALL OUT SETTINGS￿

 

10M

EMERGENCY REC DURATION

 

 

 

 

 

 

To sound a buzzer only when reaching a specified remaining HDD capacity:

1)Select “REMAIN” for “BUZZER” in the <REAR TERMI- NAL SETTINGS> screen.

2)Set the remaining capacity in “REMAIN HDD” of the <REAR TERMINAL SETTINGS> screen.

To sound a buzzer when reaching the specified remaining HDD capacity and when a warning is displayed:

1)Select “WARNING” for “BUZZER” in the <REAR TER- MINAL SETTINGS> screen.

2)Set the remaining HDD capacity (HDD MAIN REMAIN/ HDD SUB REMAIN) in “CALL OUT SETTINGS” of the <REAR TERMINAL SETTINGS> screen.

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations